City and state requirements
Colorado Building Performance Standards
Qualifying Denver buildings also have state reporting duties. Check state benchmarking and fees alongside your Denver requirements.
Read the state guidance ↗Denver covers large buildings at least 25,000 gross square feet, with a separate program for smaller buildings. Owners must report energy use and meet their assigned performance requirements. [1, 2]
Last verified Nov 10, 2026 · 7 official sources
Smaller buildings have a separate program with specified actions to complete. [1]
Buildings 25,000 ft² and larger; 2026 energy use.[3]
2028 / 2032[2]
20,000–24,999 ft².[4]
| Size | What you must do next |
|---|---|
| 25,000 ft² and larger | Report 2026 energy by June 1, 2027. Confirm your assigned target and timeline. |
| 5,000–24,999 ft² | Follow the small-building route. Buildings of 20,000–24,999 ft² must comply by December 31, 2026. |
Report energy for all uses and tenants in your building. Under stated conditions, an independently run commercial unit may get a separate Denver Building ID (DBID). The owner remains responsible. Check the technical guidance for shared systems and campuses. You cannot simply combine buildings across your portfolio. [1, 5]
Find your large building’s assigned deadlines and targets at lookup.energizedenver.org. For smaller properties, use the Small Building Look Up Tool. Check approved adjustments, extensions or other pathways with Denver’s Office of Climate Action, Sustainability and Resiliency (CASR). [2, 4]
The first verification, an independent data check, covered 2024 or 2025 data and was due June 1, 2026. Verify again after the final target year. For a 2032 target, that means June 1, 2033. Complete upgrades or your approved plan too. Reporting alone does not meet performance duties. [1, 2]
Share Portfolio Manager with Energize Denver, claim the building in the Energize Denver Management Portal and submit there. Review confirmation and correct errors. [3]
Verification and reporting after a 2032 final target year. [2]
Xcel can upload combined whole-building data to Portfolio Manager automatically. September 2026 technical guidance requires tenant consent if there are three or fewer Xcel tenants. It also requires consent if one tenant uses more than 50% of total energy. Other suppliers and delivered fuels have their own records and steps. [4, 5, 6]
Include separately metered electricity and fuels that residents pay for. Ask separately metered tenants and residents for data if utility whole-building data for an energy type is unavailable. You must also ask if you want to check the utility data. They have a duty to provide it. Before a tenant leaves, request that year’s data through their departure. [1]
Check what the combined utility data and common-area meters cover against tenant-paid records before adding data. Keep requests and consent letters or messages. A combined utility feed does not prove every fuel or account is included. [1, 5]
Compare resident-paid records with utility totals and common-area meters. Fill gaps without counting the same energy twice.
| Period | Limit · Site EUI · kBtu/ft²/year |
|---|---|
| Default multifamily target | 44.2 default |
The default apartment-building site EUI target is 44.2 kBtu/ft²/year. Here, kBtu means thousands of British thermal units, a measure of energy. Check whether your building has an approved extension to the default 2030 target year. For mixed-use buildings, the target can depend on each use's share of floor area. Approved adjustments and compliance pathways can also change it. Ask Denver to check your building’s assignment. [1, 5]
Assume a 100,000-ft² apartment building has a two-period schedule and a 5 kBtu/ft²/year shortfall. [1]
This uses the two-period rate before adjustments. Separate violations and missed extension deadlines can add penalties.
Missing benchmarking or verification can cost $2,000 each year for each violation. Performance fines depend on missing kBtu and the number of target periods. The maximum is $0.15 per missing kBtu for three periods, $0.23 for two, or $0.35 for one. Other rules cover missing benchmarks, extension deadlines, maintenance and small-building compliance. Appeals, reduced penalties and penalty reinvestment have deadlines and eligibility rules. [1]
Reconcile resident-paid usage with utility totals for your Denver energy record.
With each resident's permission, Public Grid collects actual monthly in-unit usage where property data sharing is allowed and we handle the resident's account. We export that usage for ENERGY STAR Portfolio Manager, GRESB and BPS or benchmarking reporting. You or your consultant submit the report.
Public Grid is free for owners, managers and residents. Enter your property's address to check electricity coverage.
| STATEMENT | USAGE |
|---|---|
| Sep 15, 2026Aug 14 – Sep 12 | 471 kWh |
| Aug 14, 2026Jul 15 – Aug 13 | 618 kWh |
Talk with our team about resident permission, usage records and reporting exports.
Book a demoExplore the blogDenver's benchmarking and existing-building energy-performance program, administered by CASR. Large and small buildings have different duties. [1]
Whole-building energy is required. Start with utility aggregation; the rules require tenant requests where utility data is unavailable. [1]
Benchmarking has a $2,000 annual per-violation schedule. Performance calculations depend on missing kBtu and number of target periods. [1]
Current state guidance deems qualifying Denver performance compliance, including approved adjustments and extensions, compliant with state performance targets. Both benchmarking submissions and applicable state fees remain. [7]
Last checked November 10, 2026 · 7 official sources
Confirm your building's coverage and filing route with Denver's Energize Denver team.
Building law directory →In-unit energy data →GET STARTED
Enter your property’s address to check electricity service.