Skip to content

Washington, DC BEPS
for apartment buildings

DC’s Building Energy Performance Standards (BEPS) set energy-use standards for covered buildings. If your building falls below the initial standard, you must complete an approved pathway, a plan for meeting the rules. Benchmarking means measuring yearly energy use and reporting it. That report alone does not complete your pathway. [1, 2, 4]

Last verified Nov 10, 2026 · 11 official sources

Next ordinary filing
May 3, 2027

2026 data, verification and applicable actions reports

Private BEPS coverage
≥50,000 gross ft²

Period 1; private benchmarking starts at 10,000 ft²

District-owned coverage
≥10,000 gross ft²

Includes District instrumentalities

Cycle 1 closes
Dec 31, 2026

Pathway-change and alternative-pathway applications due

Maximum BEPS payment
$10/gross ft²

Before adjustment; $7.5 million building cap

Performance Pathway
>20% decrease

Normalized/adjusted site EUI; 2026 vs. 2018–2019 average

On this page

Check your building. Confirm coverage.

Buildings below the initial standard must complete their approved pathway. Buildings that met it have no Period 1 energy-performance requirement and are reevaluated at the reset. Annual benchmarking continues.[1, 3]

  1. 01

    Check the ownership and size.

    Period 1 covers private buildings at least 50,000 gross ft². It also covers District-owned or instrumentality-owned buildings at least 10,000 gross ft². Instrumentalities are entities that act for the District. Private apartment buildings start benchmarking at 10,000 ft². Private BEPS coverage expands to at least 25,000 ft² on January 1, 2029. It expands to at least 10,000 ft² on January 1, 2035. The next standards reset is in 2029. [1, 3, 6]

  2. 02

    Check the reporting property.

    Buildings that share energy or water meters, or building systems, must benchmark as one property. Use their combined gross floor area. This rule does not let you combine unrelated buildings across your portfolio. [7]

  3. 03

    Check the building's determination and approved pathway.

    Use the disclosure/Owner Portal to see whether the building met the standard and what pathway applies. An application for delay or exemption does not establish approval. [1, 3, 4]

Prepare the record. Complete the filing.

Your assigned or approved pathway determines the Cycle 1 performance test.

  1. 01

    Confirm the property record and pathway.

    Check your approved or assigned Cycle 1 pathway in the Owner Portal; assignments were completed by April 2024. [4]

  2. 02

    Collect whole-building data.

    The Department of Energy and Environment (DOEE) directs buildings with five or more electric or gas user meters to utility aggregate data. Pepco uses EUDS; Washington Gas uses Utilli. Residential tenants are not required to provide data to landlords. [8, 9]

  3. 03

    Complete the approved pathway.

    The Performance Pathway requires a greater than 20% decrease in normalized/adjusted site energy use intensity (EUI). EUI is yearly energy use per square foot. Compare CY2026 with the CY2018–2019 average. DOEE adjusts the figures so the years can be compared. Use its metrics and method rather than raw bill totals. Other approved pathways have different tests. [1, 10]

  4. 04

    Submit eligible changes or relief requests on time.

    December 31, 2026 for pathway changes/alternative pathways; April 1, 2027 for compliance delay/exemption requests. Use the Owner Portal and current instructions. [4]

  5. 05

    Arrange independent verification before reporting.

    Have CY2026 data verified, or independently checked, before filing by May 3, 2027. Current rules require this every six years beginning in 2027. The verifier must have no relationship to the owner, manager or reporter. [4]

  6. 06

    Submit and save evidence.

    File CY2026 benchmarking and the required Completed Actions Report by May 3, 2027. You need the Performance Pathway report even if your building misses its target. Keep the signed verification checklist and supporting records at least three years after filing. [4, 10]

Your next deadlines

  1. December 31, 2026

    Cycle 1 buildings

    Cycle 1 closes; pathway-change/alternative-pathway application deadline. [2, 4]

  2. April 1, 2027

    Delay or exemption requests

    Delay/exemption request deadline. [4]

  3. May 3, 2027

    Annual report and pathway records

    CY2026 benchmarking, independent verification and applicable Completed Actions Reports due. [4, 10]

  4. January 1, 2029

    Next BEPS cohort

    Next standards established; private BEPS threshold expands to at least 25,000 ft². [1, 2]

  5. January 1, 2035

    Expanded BEPS coverage

    Private BEPS threshold expands to at least 10,000 ft²; standards recur every six years. Subsequent compliance cycles last five years. [1, 2]

Past deadlines and rule changes
  1. March 21, 2025; August 13, 2026

    Schedule amendments took effect under Law 25-307 and Act 26-416. [1]

  2. January 1, 2021

    First standards established; initial compliance cycle began. [1, 2, 3]

  3. 2018–2019

    Performance Pathway baseline years, averaged for Cycle 1. [1, 10]

Understand the calculation. Plan your response.

BEPS maximum payments and benchmarking infractions are separate.

Example; unadjusted

Assume a 100,000-gross-ft² building before pathway adjustments. [5]

Reported gross area
100,000 ft²
Maximum rate
$10/gross ft²
Before adjustment
100,000 × $10
Building cap
$7,500,000
$1,000,000 before adjustment

Maximum BEPS payment before pathway adjustments: $1,000,000. DOEE applies the adjustments for your building; separate reporting violations can carry fines.

The initial 2021 multifamily standards are an ENERGY STAR score of 66, where applicable, or Source EUI of 110.7 otherwise. These initial energy-performance standards do not set an emissions cap. Confirm your building’s eligibility, determination, approved pathway and adjusted metrics with DOEE. [3, 10, 11]

The maximum BEPS payment is the lesser of $10 × reported gross ft² or $7,500,000. College/university and hospital campuses have one $7.5 million campus cap. DOEE lowers the maximum in proportion to pathway progress. In its Performance Pathway example, a 10% site-EUI reduction against a 20% target lowers the maximum by 50%. Missing required evidence or knowingly giving wrong information can lead to the maximum payment. Separate civil infractions can add fines. This is not the full fine schedule. [5]

Benchmarking noncompliance can separately incur up to $100/day. Verification is required every six years beginning in 2027. [4, 6]

Bring resident-paid usage to your reporting team.

Reconcile resident-paid usage with utility totals for DC benchmarking and your approved BEPS pathway.

With each resident's permission, Public Grid collects actual monthly in-unit usage where property data sharing is allowed and we handle the resident's account. We export that usage for ENERGY STAR Portfolio Manager, GRESB and BPS or benchmarking reporting. You or your consultant submit the report.

Public Grid is free for owners, managers and residents. Enter your property's address to check electricity coverage.

Unit 305Active

Bills received

STATEMENTUSAGE
Sep 15, 2026Aug 14 – Sep 12471 kWh
Aug 14, 2026Jul 15 – Aug 13618 kWh

Washington, DC BEPS questions

Bring your data questions.

We can help you check electricity coverage and the resident-paid usage available for your reporting team.

Book a demoExplore the blog
Is DC BEPS an emissions cap?

The current Cycle 1 requirements use energy-performance metrics and approved pathways. Boston and NYC use different emissions formulas. [1, 10]

Does a 20,000-ft² private building have to report?

It is within the current 10,000-ft²-and-larger private benchmarking scope. That does not put it in Period 1 BEPS. [1, 6]

Does Cycle 2 begin in 2027?

Current law places the next standards and 25,000-ft² private expansion at January 1, 2029. Cycle 1 reports are due in 2027. [1, 2, 4]

Is a 20% energy reduction enough?

The current Code says greater than 20% for the Performance Pathway. DOEE calculates normalized/adjusted site EUI. Follow its calculation and the approved pathway. [1, 10]

Do residents have to hand over bills?

DOEE says residential tenants do not have to provide data to landlords. Start with utility aggregates and permissioned records. [8, 9]

Can I change pathways now?

The current deadline is December 31, 2026; an alternative pathway requires an application. Use the Owner Portal. [4]

Can I submit first and verify later?

CY2026 verification must be finished and reported before the May 3, 2027 deadline; an unverified report is not complete. [4]

Does buying data satisfy BEPS?

Usage data supports the reporting record. Owners still must meet their pathway requirements and applicable verification/reporting duties. [4, 10]

GET STARTED

Check your property’selectricity coverage.

Enter your property’s address to check electricity service.