Skip to content
BlogEnergy reporting

Energy benchmarking for apartment buildings

How to gather your building’s energy records, fill usage gaps and prepare the report your program needs.

Your team has the hallway electric bills and the central heating account. Residents pay for electricity inside their apartments, and those records aren't in the owner's files. Before entering a building total, you need to know what the records cover. First, list the data you have. Use that list to check your benchmark and any required report.

What does energy benchmarking tell an apartment owner?

Energy benchmarking measures and compares a building's energy use. ENERGY STAR says you can compare with similar buildings, past use or a reference level. You can use that benchmark to track how the building changes over time.

Portfolio Manager can track energy and water for any building, according to ENERGY STAR. To get a 1–100 ENERGY STAR score, your building must meet more requirements. For multifamily housing, at least 20 units is one criterion. That alone doesn't guarantee a score or show a nationwide legal reporting threshold.

Check separately whether you want to track use, can get a score or must file a report. Our guide to benchmarking and performance standards introduces that distinction. First ask which program, if any, requires your property to report. Then confirm which spaces and dates the report covers and which data it accepts.

This guide uses official guidance checked November 8, 2026. It offers a preparation workflow rather than a national deadline or legal coverage table.

What data should your team collect?

Gather building details and records for the energy your benchmark will cover. ENERGY STAR's starter kit has a data collection worksheet. Use it to find which details your building needs. Portfolio Manager has separate property and meter setup tools, so assemble the record before entering it.

For an ENERGY STAR score, the criteria require whole-building energy for every fuel, regardless of who pays. They also require at least twelve consecutive full calendar months for all active meters and fuels. A city's reporting period may have separate instructions. Don't apply the score criteria as if they were every jurisdiction's law.

The list below is our suggested working table. Freddie Mac's January 2026 Green Advantage guide explains owner-paid data, tenant-paid data and overlap. Its lender-program rules don't set rules for cities nationwide.

Scroll sideways to see all columns →

RecordWhat it can representWhat to check before using it
Owner-paid billsThese can cover house meters, central systems or other accounts the owner pays.Check the fuel, account and dates. Does this usage already appear in a combined total?
Utility whole-building dataThis combines property use for a particular utility.Check the meters, fuel and months. Does it cover owner-paid and resident-paid use?
Resident-paid recordsThese cover use that residents pay for directly.Check the required permission, covered units and dates. Check for overlap with other sources.
Building detailsThese show the property boundary and current uses.Check the required IDs and details about area and use. Follow the receiving program's instructions.
Missing or estimated recordsThese show known gaps or records that need special treatment.Confirm that the program accepts them. Label them clearly before sending.

Freddie Mac defines whole-property data as owner-paid plus tenant-paid usage. If the property is entirely owner-paid, its guide says separate tenant-paid data isn't needed. Confirm the arrangement before launching a resident-data request your building doesn't need.

How do you fill the resident-paid data gap?

Check what the utility can provide, then find what remains missing. ENERGY STAR's utility-data map shows utilities offering benchmarking data. Use it to locate a potential source and confirm the current offering directly with the utility.

Ask which meters, fuels and periods are included. Freddie Mac's guide explains that a utility total can combine owner and tenant use without separating them. A whole-building total therefore doesn't mean you can inspect every individual resident account.

Check aggregation before adding more bills

An aggregate is a combined total. It may already include the house meters and resident usage. Freddie Mac explicitly warns against counting owner-paid bills again when they're already included in the utility total. Keep source bills to resolve differences, then add only records that fill a verified gap.

Confirm permissions and current utility policy

Freddie Mac warns that data-sharing policies can change from year to year. Ask the utility about its current authorization requirements and available delivery method. ENERGY STAR says automatic sending depends on your location or the tracking software you already use. Neither statement shows a universal right to individual resident data.

If resident-paid usage is still missing, make a plan to get it. Record the units and periods you still need. Don't describe an incomplete set of owner bills as the whole-building record.

How do you check and benchmark the building record?

Resolve differences in scope, dates and overlap before relying on the result. The steps below are our suggested workflow, using ENERGY STAR setup guidance and Freddie Mac's data-quality practices.

  1. Define the property and purpose. Find the building being tracked and any city, state or lender reporting requirement. Confirm the receiving program's current scope and period.

  2. Gather building inputs. Use ENERGY STAR's worksheet to assemble the required property details. Assign one person to resolve differences in area, use or identifiers.

  3. List every energy source. Match bills and aggregate data to the relevant meters, fuels and months. Include resident-paid usage where the applicable whole-building record requires it.

  4. Resolve gaps and duplicates. Compare source bills with utility totals. Keep missing and estimated records visible, and ask the program how to handle them.

  5. Enter and review the record. Set up the property and meters in Portfolio Manager. Run the data-quality checker and investigate possible errors or unusual values before relying on the benchmark.

  6. Complete any required submission. If your building must report, follow the current receiving program's instructions. Keep its confirmation and review unresolved errors instead of assuming data entry completed filing.

The quality checker helps find possible problems. Use its results to help your review. They don't prove that every source and reporting boundary is correct. Source bills remain useful when your team needs to explain a value.

Once you’ve resolved those issues, compare your building’s energy use with its past use. You can also compare with a suitable peer or reference benchmark. Keep the comparison period and building boundary consistent.

Energy use intensity (EUI) means yearly energy use per unit of floor area. This is ENERGY STAR's definition. Use the same measure and basis when comparing values.

What should you submit and keep for next year?

Follow the current instructions for the program receiving the report. There isn't one national city-submission route established by the sources for this guide.

For a New York City property, start with our Local Law 84 reporting reference, then follow the City's current instructions. NYC requires a report for each building. A Building Identification Number, or BIN, marks each building. A tax-lot or portfolio total isn't automatically the correct reporting unit. The page also requires current building use and identifiers. Each meter in the report needs complete data from January 1 through December 31.

NYC requires owners to connect and share their properties with the City through Portfolio Manager to complete benchmarking. That is NYC's current process. It isn't a universal submission rule. NYC's Department of Buildings also tells owners to review the newest Covered Buildings List annually because status can change.

For your own program, keep the applicable guidance, data list, source records and submission confirmation together. Assign the next-cycle owner while the open questions are still clear. If you're also preparing GRESB reporting, our guide to actual tenant usage in GRESB covers that separate assessment context.

How Public Grid helps fill resident-paid gaps

Resident-paid units can be the missing part of an owner's building record. With each resident's permission, Public Grid collects actual monthly usage for those units where property data sharing is allowed. We export that in-unit usage for ENERGY STAR Portfolio Manager, GRESB and building performance standard (BPS) reporting.

Your team gets actual usage to help fill tenant-paid gaps or replace estimates. Public Grid supplies this data wherever it handles the resident's account. It doesn't depend on Green Button or a utility data-sharing program. That gives your reporting plan a way to include those units even where the utility doesn't offer that route.

Public Grid is free for owners, managers and residents. We supply the data; the owner or consultant submits to the relevant program. Start with the missing units and periods in your list and check electricity coverage for the property. Then discuss how the in-unit export fits your whole-building record.

Common questions

Does a 20-unit apartment building automatically get an ENERGY STAR score?

No. A multifamily property needs at least 20 units to qualify for a score. It must also meet other eligibility and data rules. ENERGY STAR also requires whole-building energy for all fuels and twelve consecutive full calendar months for every active meter. Tracking a building in Portfolio Manager is different from qualifying for a score.

Can a utility total and separate apartment bills cover the same usage?

Yes. Freddie Mac's Green Advantage guide warns against double counting owner-paid data already included in utility totals. Check for the same overlap before adding apartment bills. Confirm which meters, fuels and periods each source covers.

Can I use estimated resident usage for a city or GRESB report?

Check the receiving program's rules. Freddie Mac allows certain ways to estimate use for its lender program. A city, building performance program or GRESB may have different rules. Identify missing and estimated records, then confirm the applicable treatment before submitting.

Sources

  1. ENERGY STAR: Benchmark Your Building With Portfolio Manager (checked November 8, 2026)
  2. ENERGY STAR: Eligibility Criteria for the 1–100 ENERGY STAR Score (checked November 8, 2026)
  3. ENERGY STAR: Get Started with the Benchmarking Starter Kit (checked November 8, 2026)
  4. Freddie Mac: Benchmarking Data Collection Guide, Green Advantage Best Practices (January 2026)
  5. ENERGY STAR: Accessing utility data for benchmarking (checked November 8, 2026)
  6. ENERGY STAR: What is Energy Use Intensity (EUI)? (checked November 8, 2026)
  7. NYC DOB: Local Law 84, NYC Benchmarking Law (checked November 8, 2026)

GET STARTED

Check electricity availability for your property.It takes a few minutes.

Enter your property's address to see whether we can set up residents' electricity accounts.