It's April, and your team is filling in GRESB's Asset Spreadsheet for a 200-unit building. The common-area meters are easy, since those bills come to you. The apartments are blank, because residents pay those bills and you never see them. GRESB still scores how much of your floor area your energy data covers. This post follows GRESB's 2026 guide, so check the current one before you submit.
How GRESB scores apartment energy data
GRESB compares how real estate companies and funds manage energy, resources and other sustainability issues each year. Results aren't public. They're shared with the participant and with investors. Each year you report two years in a row of energy data for every asset. Here's how the 2026 cycle ran:
Scroll sideways to see all columns →
| Date (2026) | What happened |
|---|---|
| April 1 | Portal opened |
| July 1 | Submission deadline |
| September 1 | Preliminary results; corrections through September 15 |
| October 1 | Results released to participants and investors |
Operational energy scoring includes 8.5 points for data coverage and 2.5 points for energy performance. Data coverage is the share of your floor area, and of the year, that actual energy data covers. GRESB scores it against peers of the same property type and country, such as US multifamily mid-rise.
Why the apartments carry so much weight
You can report an asset as a Whole Building, or split it into Base Building and Tenant Spaces. GRESB says to use Whole Building only when you can't separate common-area energy from apartment energy.
Base Building means common areas and shared services, like corridors, lobbies and elevators. Tenant Space is the leasable floor area, vacant or occupied. When you split an asset this way, base building coverage carries 40% of the weight and tenant space carries 60%. If every apartment is tenant-controlled, the units drive 60% of that asset's coverage score.
Control depends on who has authority over how the space is run. Paying the bill doesn't settle it alone. Still, apartments where residents hold their own utility accounts and control their own use are usually reported as tenant-controlled.
GRESB's own example shows the stakes. Picture 10 equal-size, tenant-controlled US multifamily assets. One has 100% coverage and nine have none. Together they earn 0.85 of the 8.5 coverage points.
What counts as actual data
GRESB is direct: participants "must use actual data (i.e., non-estimated data)" when they report energy. It asks for all known usage in each space but doesn't name collection methods. In our reading, metered usage from a bill, a utility data feed or a submeter all qualify.
Estimates can only fill small gaps in actual data. They can't exceed 20% of the period with actual data, or three months across the two reporting years. They must also match the area type and the utility type.
Some shortcuts aren't allowed at all. You can't estimate from floor-area averages, from other assets, or from national benchmarks and other generic sources. So you can't take the 40 apartments that shared their usage and scale it up to cover the other 160. Report actual data for the units you have and leave the rest uncovered.
Where resident usage data comes from
The hard part is that the data isn't yours. A resident who pays the utility directly is its "customer of record." So the U.S. Environmental Protection Agency (EPA) treats the owner as a third party for that data. Owners usually get it through the utility, through residents or through the lease.
Utility whole-building data
Some utilities give owners whole-building totals, often sent into ENERGY STAR Portfolio Manager, a benchmarking tool. Utilities set privacy thresholds and authorization requirements, so ask what applies to your building.
A combined total may not separate apartments from common areas. Ask the utility which meters and spaces it includes and whether separate totals are available. If you can't separate them, confirm the Whole Building reporting route with your GRESB adviser.
Resident authorization, including Green Button
Residents can authorize their utility to share their usage with someone else. Some utilities support Green Button Connect My Data, a standard built for this. The resident sets how long access lasts and can revoke it at any time. Not every utility offers it.
This gives you actual usage by unit, which supports the Base Building and Tenant Spaces split. The downside is effort. EPA notes that collecting each authorization takes real work, and some residents won't finish.
Lease clauses
GRESB now scores lease language that supports data sharing. In the 2026 Real Estate Assessment, the green lease indicator (TC4) is worth 2.5 points. It includes requirements related to information sharing and metering.
For participants completing the Residential Component, TC4 is unscored in the residential report. An indicator called RES6 replaces it and is worth 3.5 points in the 2026 standalone Residential Benchmark Report. It asks whether leases or formal appendices cover items like residents sharing energy data with the landlord. A resident handbook given with the lease counts. Website posts, posters and email campaigns don't.
A clause earns points, but it doesn't collect usage. You still need one of the routes above.
What to watch: consent, privacy, and steady coverage
Coverage counts both area and time. A unit whose data starts in March covers only part of that year. Ask GRESB or your consultant how it treats resident meters with different start dates.
Also watch like-for-like, one of two ways to earn GRESB's 2.5 energy performance points. It compares the same space across two years. This helps show how energy use changed in that space. It needs full-year data, the same reporting level both years, and coverage that matches within 1%. In our reading, if turnover or consent changes shift your resident coverage, some space could drop out. Confirm with GRESB before counting on it.
Sharing rules for resident energy data vary by state and utility. Tell residents how you'll use their data, and respect withdrawals. GRESB itself only receives totals for each asset.
A checklist for the next cycle
GRESB says updates from its Road to Performance consultation will apply from the 2028 Standard, assessing 2027 data. Review the current assessment guide before using any of the scoring details in this post for a future cycle. Check GRESB's published assessment calendar for the next cycle. Do not carry forward the previous year's deadline without confirming it.
Pick a reporting level for each asset. Use Base Building plus Tenant Spaces where you can split the energy.
Classify each space by who has operational control.
Note each asset's data source: utility aggregate, resident authorization, or submeters.
Check your lease and its formal appendices for a data-sharing clause.
Track consent and data start dates by unit to know your area and time coverage.
Keep estimates within the 20% and three-month limits, and leave unknown area uncovered.
Look for gaps in the Asset Portal's Live Data tab before the deadline.
How Public Grid helps
Public Grid collects real usage for resident-paid units with each resident's permission. Data sharing must also be allowed for the property. It exports your in-unit usage for ENERGY STAR Portfolio Manager, GRESB and building performance standard (BPS) reporting. You or your consultant use that data to prepare and submit the reports. We collect this usage wherever we handle the resident's account. The utility doesn't need to offer Green Button Connect or another data-sharing program.
The portal shows that unit's bills and electric usage in kWh. Buildings with gas also show gas usage in therms. That's bill-level usage by unit, the kind of actual data GRESB asks for. Utilities sometimes estimate a bill, so check that the bills you count were based on actual reads. Units without consent don't show usage and should stay uncovered.
Portfolio electric analytics mix actual usage with estimates. Use only the actual figures for GRESB. Public Grid is free for owners, property managers and residents, helping your team fill tenant-paid data gaps before the next submission.
Common questions
Can we estimate usage for units that didn't share their data?
Not by scaling up from other units. GRESB doesn't allow estimates based on floor-area averages, other assets, or generic data. Report actual data where you have it and leave the rest uncovered. Small gaps in otherwise actual data can be estimated within GRESB's 20% and three-month limits.
Is the utility's whole-building total enough?
It can give strong coverage at the Whole Building level where your utility offers it. Check whether the utility can separate apartments from common areas. Availability, privacy thresholds and authorization requirements depend on the utility.
Are units tenant-controlled if residents pay their own bills?
Not automatically. GRESB bases control on who has authority over how the space is run. Apartments where residents hold their own utility accounts and control their own energy use are usually reported as tenant-controlled.
Sources
- GRESB: Key dates, GRESB assessments timeline
- GRESB: Real Estate Standard Road to Performance public consultation
- GRESB 2026 guide: Reporting scope
- GRESB 2026 guide: Data sharing and confidentiality
- GRESB 2026 guide: Performance Component
- GRESB 2026 guide: Energy
- GRESB 2026 guide: EN1 Operational energy
- GRESB 2026 guide: EN1 Reporting level and data availability
- GRESB 2026 guide: Estimation rules
- GRESB 2026 guide: 2026 Standard updates
- GRESB 2026 guide: TC4 Sustainability requirements in lease contracts (green leases)
- GRESB 2026 guide: Residential Component
- GRESB 2026 guide: RES6 Sustainability elements in lease contracts
- GRESB 2026 guide: Asset Portal guide
- GRESB 2026 guide: What's new
- EPA: Guidance for Utilities on Providing Whole-Building Energy Data to Enable Benchmarking in ENERGY STAR Portfolio Manager (July 2023)
- ENERGY STAR: Data access and benchmarking for utilities
- Green Button Alliance: Green Button Connect My Data