City and state requirements
Washington Clean Buildings
Seattle buildings may also have state Clean Buildings duties. Classify the state tier separately from Seattle's emissions targets.
Read the guide →Official source ↗Report your building's energy use each year and prepare for emissions targets and checks. Seattle covers buildings over 20,000 gross square feet. The targets and verification start in phases. [1, 2, 3]
Last verified Nov 10, 2026 · 10 official sources
Check whether your building is over 20,000 ft², excluding parking. Some garden-style communities have only individual buildings of ≤20,000 ft². A larger community total alone does not bring them under BEPS. Residential condos can be covered, and their associations can count as owners. [2, 3, 6]
Qualifying R-2 or R-3 buildings count as multifamily under BEPS. More than 50% of the building must be residential for this class. Factory-industrial and other listed exceptions need the proof the rule calls for. An owner's statement alone is not enough. [3]
Use the Seattle Benchmarking Map to see estimated targets and schedules. Use the Energy Benchmarking Compliance Lookup Tool to check each data year's status. Ask OSE to resolve your OSE ID and any connected buildings, campuses or approved portfolios. Do this before you use a grouped schedule. [1, 2, 5]
Include every fuel source for common and tenant spaces. Collect twelve months for each active meter. Check parking details and any secondary property uses. [7]
Use your OSE ID to share with City of Seattle Annual Reporting. The current hub directs buildings that have not met the rules to the Seattle Building & Energy Portal. Create an account there and complete your submissions. A Not Submitted or Pending Revisions status means you need to act. [5, 7, 8]
Complete Benchmarking Verification and the GHG Report by your October 1 deadline. Verification is a check of your energy data. The first check covers the prior year. The report lists equipment, targets, proposed actions and records for any alternatives or deductions you use. [2, 3]
Use the right targets for your building's activities, emissions factors and allowed deductions. An emissions factor converts energy use into greenhouse gases. Get approval for custom plans or combined targets where needed. The rule can excuse all-electric buildings from the GHG Report. They still need verification and benchmarking. [2, 3]
Keep bills, meter lists, checked inputs and outputs, and Qualified Person records. Also save portal confirmations and proof for any approved plan or deduction. Renewable-electricity attestation records have specific reporting duties in later years. Follow §12.07; one report may not close the interval. [3]
| Building size | First verified GHG report due |
|---|---|
| Over 90,000 ft² | October 1, 2027 |
| 50,001–90,000 ft²; portfolios, district campuses and connected buildings | October 1, 2028 |
| 30,001–50,000 ft² | October 1, 2029 |
| 20,001–30,000 ft² | October 1, 2030 |
Verification cohorts follow the City’s adopted schedule.[2, 3]
The default multifamily net-zero interval. This does not set a universal January 1, 2041 multifamily deadline. [3]
Rulemaking update: comments on draft benchmarking rule 2026-01 close November 23, 2026 at 5 p.m. Existing reporting deadlines remain in effect.[5]
Report all energy use for common and tenant spaces, for all fuels and all twelve months. City Light electricity, Puget Sound Energy (PSE) gas and district steam use different data services. Current City instructions say PSE needs a customer release for two or fewer tenants. [7]
City Light offers automated benchmarking requests for Portfolio Manager, the energy reporting tool. It also has separate Consumption Report Release forms for individual accounts. Those forms use “1–4 units” and “5 or more units” groups. The page says those reports are not for Portfolio Manager. Ask City Light which permissions your building needs for automated benchmarking. [9]
Use Seattle's factors to convert fuel energy to emissions, then add the kg CO2e. Divide that total by gross ft² to find emissions intensity, the amount per square foot. Purchased electricity has a low but nonzero factor in the first interval. Specific conditions apply to “all-electric” treatment. [2, 3]
Compare resident-paid records with utility totals and common-area meters. Fill gaps without counting the same energy twice.
| Period | Limit · GHG intensity · kg CO2e/ft²/year |
|---|---|
| 2031–2035 | 0.89 |
| 2036–2040 | 0.63 |
| 2041–2045 | 0.37 |
| 2046–2050 | 0.00 |
Default Multifamily Housing greenhouse gas intensity targets use the allowed compliance-year method. Check mixed activities, separate senior-living values and approved alternatives. Future rules may change later targets. [3]
Assume a 100,000-ft² ordinary multifamily building misses its emissions target or approved alternative. Low-income and low-rent housing use a different rate. [3]
This penalty applies once per compliance interval, 360 days after the deadline. Appeals can adjust the amount; low-income and low-rent housing have a different rate.
BEPS has separate penalties for reports and targets. Missing, wrong or incomplete reports cost $15,000 for >50,000 ft² and $7,500 for ≤50,000 ft². Failure to meet a target or approved alternative uses these rates: $10/ft² nonresidential, $7.50/ft² multifamily, $2.50/ft² low-income or low-rent housing. Penalties are imposed 360 days after the deadline, once per compliance interval. They do not apply every year. Appeals can change amounts. [3]
Tenant access or information violations have a separate schedule. Spaces >20,000 ft² use the building-category rates above. Spaces of 5,000–20,000 ft² use $2,500; those <5,000 ft² use $500. Other state and city restrictions qualify tenants' duties. [3]
For benchmarking, the current City page lists yearly fines of $4,000 for buildings ≥50,000 ft². It lists $2,000 for the smaller covered tier. Assessment comes 90 days after the reporting deadline. Wrong reports, failure to disclose and tenant information violations can bring $500 fines. The City has waived failure-to-report fines for 2025 data during the new portal transition. [6]
An alternative compliance payment (ACP) is available only in the 2031–2035 interval. The current rule compares two amounts and uses the greater one. The first is $1,250 for ≤50,000 ft² or $2,500 for >50,000 ft². The second is annual excess metric tons × 5 × $190. The payment is capped at the target-failure penalty that applies. Required rulemaking can change the carbon price, so this does not guarantee a 2031 bill rate. [3]
Options include standard, alternate or combined GHG intensity targets. Other routes include first-interval ACP and multifamily prescriptive compliance, which requires specified work. Approved net-zero, low-emissions or district-campus decarbonization plans are also options. The prescriptive route requires the equipment and operating measures in the rule. Buying usage data does not complete that work. [2, 3]
Extensions can cover eligible new construction, financial distress, high rental vacancy (≥35%) or ownership changes. Qualifying low-income, low-rent or human-services uses may also qualify. Many extensions delay targets while keeping verification and reporting due. A low-income first-interval extension is not a permanent exemption. Cooking emissions can be deducted in the first two intervals. Qualifying private district-energy contracts from before June 1, 2024 have a first-interval deduction. Check exact eligibility and required proof. Keep reporting fuel data. [2, 3]
Reconcile resident-paid usage with utility totals for Seattle benchmarking and emissions reporting.
With each resident's permission, Public Grid collects actual monthly in-unit usage where property data sharing is allowed and we handle the resident's account. We export that usage for ENERGY STAR Portfolio Manager, GRESB and BPS or benchmarking reporting. You or your consultant submit the report.
Public Grid is free for owners, managers and residents. Enter your property's address to check electricity coverage.
| STATEMENT | USAGE |
|---|---|
| Sep 15, 2026Aug 14 – Sep 12 | 471 kWh |
| Aug 14, 2026Jul 15 – Aug 13 | 618 kWh |
Talk with our team about resident permission, usage records and reporting exports.
Book a demoExplore the blogNo. Seattle measures emissions per square foot. Washington's state program has its own energy and reporting rules for each tier. Agencies and deadlines differ. [2]
Missing a target uses $7.50/ft², or $2.50/ft² for qualifying low-income or low-rent housing. This applies once per interval. Process and adjustment rules apply. [3]